Fuel Polishing Solutions
Recirculating diesel fuel polishing for clean, reliable fuel in storage tanks, generators, boats and fleets
Designed For Technical Professionals
Our fuel polishing solutions serve engineers and operators who store and move diesel — from standby generators and marine vessels to industrial sites and fleet fuel storage — with Dieselcraft systems for portable and stationary tank cleaning.
Marine operators & ship owners
Power plants & generator operators
Industrial facilities
Fleet & fuel storage operators
Maintenance and reliability engineers
Why Fuel Polishing Matters
Water and sediment reaching the engine
Microbial growth (diesel bug) in fuel systems
Premature filter clogging
Injector and fuel pump wear
Engine downtime and unexpected failures
ANKORZ Solution Overview
Removes over 99% of water
10-micron final filtration
Filterless primary purifier — no element to replace
Models from 420 GPH to 1,200+ GPH
How a Fuel Polishing System Works
Fuel Is Drawn from the Tank
1
Primary Separation
2
10-Micron Filtration
3
Magnetic Fuel Conditioning
4
Monitoring
5
Polished Fuel Returns or Transfers
6
Fuel Polishing Systems
FPS-HC15 – Compact Diesel Fuel Polishing System
Purpose:
When to Use:
- Intermediate polishing jobs in tanks, boats, generators and trucks
- Portable use: 65 lb dry weight with T-handle carry
- Plug-in 115 V operation (rated 450 gal / 30 min)
Case of 12 filters included
- DOWNLOAD DATASHEET
FPS-400 – Diesel Fuel Polishing System
Purpose:
When to Use:
- Polishing jobs from 50 to 1,200 gallons
- Boats, standby generators and fleet trucks
- 420 GPH rated flow with magnetic fuel conditioner
12 spin-on filters included
- DOWNLOAD DATASHEET
FPS-30 – Stainless Steel Fuel Polishing System
Purpose:
When to Use:
- Polishing jobs of 2,000 gallons and larger
- Bulk storage tanks and standby generator tanks
- Optional pre-filter and digital timer available
6 filters included — dual change-indicator gauges
- DOWNLOAD DATASHEET
FPS-400S – Stationary Fuel Polishing System with Fire-Resistant Hose
Purpose:
When to Use:
- Fixed installations on diesel storage tanks
- Transfer and recirculation polishing
- Applications needing a fire-resistant, MSHA-approved hose
12 spin-on filters included
- DOWNLOAD DATASHEET
How to choose the right fuel polishing system
Start with the job size and duty, then compare the four systems against your tank volume and site power.

FPS-HC15
Need a compact, portable system
Compare the FPS-HC15 with your job size, weight limits and available power. Confirm against the current model data sheet.

FPS-400
Polishing 50 to 1,200 gallons
Include the FPS-400 for intermediate tank jobs. Match its flow with your tank volume and hose reach.

FPS-30
Planning a 2,000-gallon-plus job
Compare the FPS-30 for larger tanks needing over 1,200 GPH, and review the optional pre-filter and digital timer.

FPS-400S
Fixing a system to a storage tank
Consider the FPS-400S for stationary tank installations that need a fire-resistant hose.
When should you assess fuel polishing?
Consider polishing for diesel that sits in storage tanks, boats and standby generators, or when you see water, sediment or filter clogging. Test the fuel first, then decide between polishing and replacement based on the results.
A clear selection workflow
- Define the tank size, fuel type and contamination condition.
- Test the fuel (water, sediment, microbial) before treatment.
- Check site power, hose reach, connections and mounting.
- Compare the current model data sheets with your job size.
- Confirm suitability with our technical team and plan follow-up testing.
Do not choose by tank volume alone — confirm flow, power and hose reach as well.
Need help choosing a model
Share your tank size, fuel type, flow requirement and site power so we can recommend a system.
Read the Complete Fuel Polishing System Selection Guide
We confirm suitability against the current Dieselcraft data sheet.
Frequently Asked Questions (FAQ)
What is fuel polishing and does ANKORZ offer it through Dieselcraft in Saudi Arabia and the UAE?
Fuel polishing is the process of circulating stored diesel fuel through filtration systems to remove water, sediment, and microbial contamination without draining or replacing the fuel. It is typically needed for fuel stored over extended periods — such as backup generators, marine tanks, or reserve fuel systems — or as preventive maintenance before contamination causes engine or filter damage. As Dieselcraft USA’s Strategic Fuel Solutions Partner across the Middle East & GCC, ANKORZ provides access to Dieselcraft’s portable fuel polishing technology alongside its diagnostic test kits (DS-1, W-5, FCT-100), so operators in Saudi Arabia and the UAE can both diagnose fuel condition and act on it through one regional partner.
Does fuel polishing restore old or contaminated diesel fuel used by generators in Saudi Arabia and the UAE?
Fuel polishing can significantly improve fuel quality by removing contamination, sludge, water, and particulates through specialized filtration and water separation equipment. However, severely oxidized fuel may still require partial replacement depending on laboratory test results — fuel polishing restores fuel condition, it does not reverse chemical oxidation that has already progressed too far. The correct sequence is test first (water, sediment, microbial, oxidation stability), then decide between fuel polishing, partial replacement, or full replacement based on actual results — rather than polishing as a default fix without knowing what is actually wrong with the fuel.
How long can diesel fuel be stored before it goes bad in Saudi Arabia and UAE climate conditions?
Untreated diesel fuel may begin degrading within 6–12 months. Properly stabilized diesel can sometimes last 18–24 months, but fuel older than 2 years should always be tested for oxidation, water contamination, sludge, and microbial growth before use. This timeline is a general baseline; fuel stored in tanks exposed to temperature swings, moisture, or partial fill levels can begin deteriorating sooner — conditions common in Saudi Arabia and the UAE, where standby generators at hospitals, data centers, and industrial facilities often hold fuel for extended periods between activation.
What are the warning signs of contaminated diesel fuel that operators in Saudi Arabia and the UAE should watch for?
Common symptoms of contaminated diesel fuel include: high fuel temperature alarms, frequent fuel filter plugging, dark or cloudy diesel fuel, black slime inside tanks, hard starting on generators, injector noise, generator shutdown under load, and water separator alarms. Any one of these signs on its own can have multiple causes, but their combination — particularly filter plugging alongside a temperature alarm — points strongly toward fuel-quality contamination rather than a purely mechanical fault. ANKORZ recommends treating any two or more of these symptoms together as a trigger for immediate on-site testing (water, sediment, and microbial checks) rather than waiting for the next scheduled annual test.
Can old diesel fuel cause a high fuel temperature warning on generators in Saudi Arabia and the UAE?
Yes. Old diesel fuel can oxidize, form sludge, collect water contamination, and restrict fuel flow. These problems increase injector return fuel temperatures and can trigger high fuel temperature alarms on generators and diesel engines — a warning operators in Saudi Arabia and the UAE should not dismiss as simply “hot weather,” since ambient Gulf heat compounds an underlying fuel-quality problem rather than causing it alone. Restricted fuel flow from clogged filters has the same effect: it forces the fuel system to recirculate heated fuel, further increasing return fuel temperature.
What is “diesel bug” and how does ANKORZ help operators in Saudi Arabia and the UAE prevent it?
“Diesel bug” is microbial contamination in diesel fuel — bacteria and fungi that grow at the interface between fuel and water inside a tank, producing byproducts that clog filters, corrode tank surfaces, and reduce fuel quality. Since microbial growth cannot establish without water in the fuel, prevention starts with water control. Testing for microbial contamination with Dieselcraft’s DS-1 kit takes 24–36 hours to develop a reliable result. ANKORZ provides the DS-1 Fuel Microbial Contamination Test Kit for on-site sampling in Saudi Arabia and the UAE, combined with proper tank maintenance and periodic fuel polishing for stored fuel.
Which Dieselcraft fuel polishing system is right for my application?
Match the system to the job size and duty. The FPS-HC15 is a compact, portable system for intermediate polishing jobs (rated 450 gal / 30 min, 65 lb dry weight). The FPS-400 is a modular system for jobs of 50 to 1,200 gallons (420 GPH rated flow). The FPS-30 is a stainless-steel system for 2,000-gallon and larger jobs (over 1,200 GPH). The FPS-400S is a stationary system for diesel storage tanks with a fire-resistant hose. Share your tank size, fuel type and site power with our technical team and we will confirm the right model against the current data sheet.
Can I use a Dieselcraft fuel polishing system with gasoline?
No. Dieselcraft fuel polishing systems are for diesel fuel only and are not for use with gasoline.
Do the systems run on the power supply available in the Gulf?
The standard FPS-HC15, FPS-400, FPS-30 and FPS-400S are specified with 115 V motors (the FPS-HC15 as 115 V / 60 Hz single-phase). Voltage and frequency differ across Saudi Arabia, the UAE and the wider Gulf, so please share your site power with our technical team before ordering so we can confirm suitability with Dieselcraft.
How does the ANKORZ RFQ process work for sourcing Dieselcraft fuel equipment in Saudi Arabia and the UAE?
Businesses in Saudi Arabia, the UAE, and across the GCC can submit a Request for Quotation (RFQ) directly through ankorz.com to source Dieselcraft fuel equipment and related industrial products. ANKORZ sources from verified manufacturers and aims to return quotations within 24–48 hours, connecting buyers to trusted supply without requiring direct negotiation with multiple manufacturers.
Is ANKORZ an authorized Dieselcraft distributor in Saudi Arabia and the UAE?
Yes. ANKORZ is Dieselcraft USA’s Strategic Fuel Solutions Partner across the Middle East & GCC, operating from Saudi Arabia and the UAE with coverage extending to Oman and the wider Gulf and Arab world. Dieselcraft Fluid Engineering — a division of Magnum Group, in fuel and oil cleaning technology since 2002 — brings expertise across industrial, marine, and power generation applications.
Fuel care works best as a sequence
Polishing cleans the tank. Test before and after to prove it, and add purification to protect fuel at the point of use.
Know what you are treating
Water, particles or microbial growth? A quick field test tells you what the fuel needs before you choose equipment.
Explore Fuel TestingProtect fuel at the point of use
Filterless purifiers separate free water and heavy contamination on the way to generators, pumps and equipment.
Explore Fuel PurificationClean the fuel already in your tanks
Portable and stationary polishing systems recirculate stored diesel until it tests clean.
Not sure where to start? Share your tank size, fuel type and site power, and our technical team will recommend the next step. Talk to the technical team
Ready to Protect Your Fuel System?
Contact our team for fuel polishing solutions tailored to your tank, generator or fleet requirements.
- sales@ankorz.com
Request Fuel Equipment or Parts
Tell us which fuel product or replacement part you need. Share specifications or a photo, and our team will review availability and contact you.
