Diesel Fuel Microbial Test Kit

The Diesel Fuel Microbial Test Kit is a fast and affordable way to detect the presence of the “diesel bug” before it clogs filters, corrodes tanks, or causes costly engine failure.

The sterile paddle is coated with two types of agar—one side for bacterial growth and the other for yeast and mold—so you can identify the type and severity of contamination without sending samples to a lab.

How it works:

Simply take a sample from the lowest point in your fuel tank, dip the paddle, return it to the vial, and incubate at room temperature (21–29°C). Within 24–72 hours, you’ll see clear results that can be compared against the included chart. No lab equipment or special training required.

Why use it:

Early detection of microbial growth saves you money, prevents unexpected downtime, and extends the life of your engines and storage systems. It’s suitable for diesel, biodiesel blends, and heating oil tanks, making it a critical tool for anyone relying on stored fuel in Saudi Arabia and worldwide.


Applications

The Diesel Fuel Microbial Test Kit is essential for anyone who stores diesel or biodiesel fuel. Regular testing prevents contamination issues in:

  • Marine vessels and yachts – highly prone to microbial growth in fuel tanks.

  • Emergency backup generators – critical for hospitals, data centers, and government facilities in KSA and globally.

  • Agriculture and farm tanks – protect tractors, irrigation systems, and harvest machinery.

  • Trucking and transport fleets – ensure clean fuel for long-haul and regional transport.

  • Construction and heavy equipment – safeguard excavators, cranes, and on-site machinery used in mega projects.

  • Home heating oil tanks – maintain clean fuel for reliable heating in residential storage.


How to Use

Testing your diesel fuel is simple and effective:

  1. Take a sample from the lowest point of the fuel tank, where water and microbes collect.

  2. Dip the sterile slide into the sample for 10–15 seconds.

  3. Let excess fuel drain off and place the slide back into its protective vial.

  4. Store the vial upright in a dark place at room temperature (70–85°F / 21–29°C).

  5. Check the slide at 24, 48, and 72 hours, then compare results to the provided chart.

Action Step: If microbial growth is detected, treat your fuel with a biocide and schedule a tank cleaning. In Saudi Arabia, this is especially important for marine vessels, generator tanks, and fleets exposed to extreme heat and humidity.


Why Choose This Kit

  • Early detection of diesel bug – prevents clogged filters, tank corrosion, and engine failures.

  • Designed for Saudi conditions – accurate even in high-heat and humid environments.

  • Essential for critical power systems – protects hospitals, data centers, and government facilities.

  • Protects valuable assets – from Red Sea vessels to transport fleets crossing desert highways.

  • Cost-effective – saves money on tank cleaning, repairs, and downtime.

  • Simple process – dip, incubate, and read results in 24–72 hours.


Technical Information

  • Product Name: Diesel Fuel Microbial Test Kit

  • Purpose: Detects microbial contamination in diesel and biodiesel fuels.

  • Detects: Bacteria, yeast, and mold.

  • Method: Dip slide with dual agar coating (bacteria + yeast/mold).

  • Incubation: 24–72 hours at room temperature (21–29°C).

  • Sample Point: Taken from tank bottom (fuel/water interface).

  • Shelf Life: 9–12 months (when stored cool and dry).

  • Applications: Marine, backup power, agriculture, fleets, construction, home tanks.

  • Compliance: Suitable for Saudi Arabia’s hot, humid climate and global use.

FAQs

  • What is a Diesel Fuel Microbial Test Kit used for?

    It is designed to detect harmful microbes—bacteria, yeast, and mold—that grow in diesel, biodiesel, and heating oil tanks, preventing clogged filters, sludge, and engine failure.

  • Is diesel bug a common problem in Saudi Arabia and hot climates?

    Yes. High heat and condensation inside fuel tanks create the perfect environment for microbial growth, making regular testing essential in Saudi Arabia and other warm, humid regions.

  • How often should I test my diesel storage tanks or generators?

    For general use, testing every 3–6 months is recommended. In Saudi Arabia, backup generators for hospitals, data centers, and fleets should be tested every 3–4 months due to faster microbial growth.

  • Can this test kit be used for marine fuel, biodiesel, and heating oil?

    Yes. It is suitable for diesel, biodiesel blends, home heating oil tanks, and marine vessels such as yachts and fishing boats, which are especially prone to water contamination.

Diesel Fuel Microbial Test Kit

Easy dip-slide test kit that detects bacteria, yeast, and mold in diesel, biodiesel, and heating oil. Get visual results in 24–72 hours to stop fuel damage before it starts.

$ 25.00

Industrial Features

    • Prevents costly downtime and repairs
    • Gives clear visual results in 24–72 hours
    • No lab equipment or training required
    • Dual-sided agar slide for bacteria and fungi
    • Reliable testing for diesel and biodiesel fuels

Technical Specifications

Product Type: Dual-Sided Microbial Dip Slide
Detects: Bacteria, Yeast, and Mold
Incubation Time: 24–72 Hours at 21–29°C
Sample Location: Tank Bottom (Fuel/Water Interface)
Shelf Life: 9–12 Months (Stored Cool and Dry)
Applications: Marine, Generators, Agriculture, Fleets, Construction, Home Tanks